● Experiments The Radiator & Heater Core of the wide selection
● The various safety device is embodied
● Controls all functions from software
● Guarantees the test which is stabilized
● Supports a calibration mode (S/W)
● Also the order production for the customer is possible
 
- Feature -
 
Test room - Chamber
Air Compressor & Reservoir
Tank - Vibration & Sound
arresting prevention
Compressed air contro l -
Flow control
Cooling & Heating System -
Tank Insulation, Level
Sensor, Flowmeter
Control Panel - Controller,
Counter, Timer & Indicator
Instrumentation - Sensor &
Converter
DAS - Field Point & Labview
S/W
Test Example - Cooling
Water : 40'C, 100lpm, 3bar - Compressed Air : 2min
(600'C, 200kg/hr, 3bar)
1min(off)
   
   
- Specifications -
 
MODEL
SEOUL-NVH-100Series
System
Test Room, Air Receiver Tank, Gas Burner, Refrigerator
Gas Burner
Max 600,00kcal/hr , 60NMF/hr, LPG
Safety device
Heater E.O.C.R, SCR Over Current, Pressure H.P S/W High Temperature : High Limit cut off
Coolant Flow Control
Pump RPM Control & By-Pass Control Valve, PID
Test Loop
Sus pipe 50A
Exterior material : Steel Pate(1.2T)
Screw Compressure
885.6kg/h
Main Heating System
Electric SUS Sheathed Heater 440V 220kW
Mass Flowmeter
Gas : 1088kg/hr, 81.6kg/hr, Max 41.3bar
Coolant : 250 lpm, Max 41.3bar
Refrigerator
10HP (GAS R-22) , Hermetic
Test Room
1100(W) * 1100(H) * 600(D)
Insulation: Ceramic Wool
Coolant Pump
0 ~ 20 bar, 333 LPM, Liquid Temp.:-40~180degree
Heat Exchanger
225,000kcal/h, 3150(L)*1120(H)*2100(W)
Construction
Material
Rolled Acrylic & Stainless & Aluminum
Sizing
 
Control
Control
Manual / Full Automatic
Control Interface
LabVIEW SoftWare With PC Interface