Home
English
Japanese
 
 
 
¡Ü Hot and Cold Test
¡Ü Power and temperatrue cycling test
¡Ü Thermal stabilization test
¡Ü Humidity heat cycle test
¡Ü Humidity heat constant test
 
 
- Feature -
 
Cooling Module, Motor Valve
,Blower Test
Fuzzy contor system
Walk-in type humidity and
temperature chamber
Utilized for the test of
a large spcimen or a large
quantity specimen
The safety devices consis
of over current relay and
various fuses and all the
dangerous factors are
removed effecttively
Wide control range
HCFC Refrigerator
Low noise level
Through PLC based touch
screen, also available
through LabVIEW¢ç
Programmable DC power
supply
   
 
- Specifications -
 
MODEL
SEOUL-NVH-100Series
Temperature Control Range
-50¡É ¡æ 150¡É
Temperature Drop Time
25¡É ¡æ -40¡É (in 40 min)
Temperature Warm Up Time
25¡É ¡æ 150¡É (in 30min)
Humidity Control Range
10 ~ 98%RH (at 10 ~ 60¡É)
FrontalAir Speed Simulator
0 ~ 120 km/hr (33 m/s)
Test Sample
Condenser, Radiator, Fan Module
Software Specification
Testsequence Setup, Graphical Display,
Chart Display
Construction
Insulator + Isolator + Wedge
Chamber Materia l & Dimension
Urethans + SUS, 2700(W)x2000(H)x1800(D)
AHU
Refrigeration 2Stage
Control Panel
Manual / Full Automatic