Home
English
Japanese
 
 
 
● A/C System field simulation pattern system test  
● Cooling system bench test ( Evaperator,Condenser)
● Compressor durability test
● HVAC NVH test / Cooling module NVH test
● FFT Analyzer for NVH test
● Coolant temperature & Flow test
● Various automatic pattern test 
 
- Feature -
 
Construction equipment test
Compressor condition
setting & control
Air speed test for condenser
FFT Analyzer for NVH test
HVAC NVH test
Coolant flow & Temperature control
Measuring comp torque by torque detector
Alarm measuring system
Measurement apparatus
status
Data acquisition system ,150 channel
Programmable DC power
supply
Blower RPM measuring
CCTV , Remote network
monitoring
Through PLC based touch
screen, also available
through LabVIEW®
Fire extinguisher preparation
Facility working state display panel
- Specifications -
 
MODEL
SEOUL-FSP-1000Series
Condenser Room
Control
Temperature : -40 ~ 80℃ , ±0.5℃
Humidity : 20 ~ 90%RH (20 ~ 60℃,±5%)
Evaperator Room
Control
Temperature : -40 ~ 80℃ , ±0.5℃
Humidity : 20 ~ 90%RH (20 ~ 60℃,5%)
Compressor Room
Control
-40 ~ 120℃ , ±0.5℃
Compressor Speed
0 ~ 12000 RPM
Compressor Torque
0 ~ 200 N.m
Condensor Velocity
0 ~ 15m/s (0.32m×0.32m, 5m/s Pressure : 20mAq)
Comp Pressure
Discharge : 0 ~ 35kg/㎠ , Suction : -0.5 ~ 1.5kg/㎠
HVAC Control
Front / Rear
Power Supply (30V,50A) , Programmable Type
Coolant Supply
Front / Rear
Temperature : 0 ~120℃ , Flow : 0 ~ 35 LPM
Refrigerant
R134a
R744(CO2 ) R1234yf
CCTV System
Pan/Tilt/Zoom , DVR , Remote network monitoring
FFT Analyzer
Noise : Sound level meter , MIC
Vibration : Accelermeter(ICP, 10mV/g , High temp)
Construction / Control
Material
Poly Urethane + Steel plate + Board
Test Room
Condenser room : 3000(L) × 2800(D) × 3200(H)
Evaperator room : 5000(L) × 2800(D) × 3200(H)
Control Manual / Full automatic
Control Interface Directreading / LabVIEW softWare with PC interface