Home
English
Japanese
 
 
 
● Bus A/C Performance Test , Condenser & Evaperator & Heat
   exchanger  
● Heat exchanger external pressure drop (Condenser,
   Evaperator)
● Heat exchanger module’s thermal performance
● Heat exchanger module’s Intake/Outlet temperature test  
● Condenser icing test
● Compressor's efficiency , Performance factor test
● Various performance pattern test
 
- Feature -
 
Construction equipment test
Compressor condition
setting & control
Measuring comp torgue by
torque detector
Air conditioner's system
matching
Heat exchanger's thermal
distribution
Each room environment
control
Calculate efficiency ,
compressor power Enthalpy
, Entropy , Sub Cool,
Superheat specific volume ,
Heat balance
Alarm measuring system
Measurement apparatus
status
Data acquisition system ,120
channel
Blower RPM measuring
Through PLC based touch
screen, also available
through LabVIEW®  
Fire extinguisher preparation
Facility working state display panel
- Specifications -
 
MODEL
SEOUL-BAC-1000Series
Condenser Room
Control
Temperature : 20 ~ 50℃ , ±0.5℃
Evaperator Room
Control
Temperature : 0 ~ 50℃ , ±0.5℃
Humidity : 30 ~ 90%RH (20 ~ 60℃, ±2.5%)
Compressor Speed
600 ~ 4000 RPM
Compressor Torque
0 ~ 1000 N.m
Driving Motor
80HP, 3 Phase , 220V
Nozzle
Condenser room : 4.0" + 6.0" + 7.0" + 7.0"
Evaperator room : 2.0" + 4.0" + 7.0" + 7.0"
Air Flow Range
Condenser room : 10,000 CMH (at 20℃)
Evaperator room : 7,000 CMH (at 20℃)
Velocity
Under 1.0m/s around test sample
Blower
Tubo fan 20HP / 10 HP
Anechoic Room
Poly urethane
200 x 200 x 200
Refrigerant
R134a
R744(CO2 ) R1234yf
Heat Rejection
Capacity
Condenser : 45,000 kcal/h
Evaperator : 30,000 kcal/h
Construction / Control
Material
Poly Urethane + Steel plate + Board
Test Room
Condenser room : 5,000(W) ⅹ 3.000(H) ⅹ 5.000(L)
Evaperator room : 5.000(W) ⅹ 2.500(H) ⅹ 6.000(L)
Wind Chamber Condenser room : 1,500(W) x 2,200(D) x 1,500(H)
Evaperator room : 1,000(W) x 2,200(D) x 1,000(H)