● Car A/C Performance Test , Condenser & Evaperator & Heat
     exchanger  
● Heat exchanger external pressure drop (Condenser,
     Evaperator)
● Heat exchanger module’s thermal performance
● Heat exchanger module’s Intake/Outlet temperature test  
● Evaporator icing test
● Compressor's efficiency , Performance factor test
● Various performance pattern test
 
- Feature -
 
Construction equipment test
Compressor condition
setting & control
Measuring comp torgue by
torque detector
Air conditioner's system
matching
Heat exchanger's thermal
distribution
Each room environment
control
Calculate efficiency ,
Compressor power Enthalpy
, Entropy , Sub Cool,
Superheat specific volume ,
Heat balance  
Alarm measuring system
Measurement apparatus
status
Data acquisition system ,140 channel
Blower RPM measuring
Through PLC based touch
screen, also available
through LabVIEW®
Fire extinguisher preparation
Facility working state display panel
- Specifications -
 
MODEL
SEOUL-CAC-1000Series
Condenser Room
Control
Temperature : -35℃ ~ 80℃ , ±0.5℃
Evaperator Room
Control
Temperature : -35 ~ 80℃ , ±0.5℃
Humidity : 30 ~ 90%RH (20 ~ 60℃ , ±2.5%)
Compressor Room
Control
-10 ~ 120℃
Compressor Speed
600 ~ 8000 RPM
Compressor Torque
0 ~ 200 N.m
Driving Motor
40HP, 3 Phase , 220V
Nozzle
Condenser room : 6.0” + 7.0” + 7.0” + 8.0”
Evaperator room : 0.75” + 1.0" + 2.0” + 3.0"
Air Flow Range
Condenser room : 14,000 CMH (at 20℃)
Evaperator room : 900 CMH (at 20℃)
Velocity
Under 0.5m/s around test sample
Blower
Tubo fan 20HP / 5HP
Refrigerant
R134a
R744(CO2 )
R1234yf
Heat Rejection
Capacity
Condenser : 10,000 kcal/h
Evaperator : 5,000 kcal/h
Construction / Control
Material
Steel plate + Board + Stainless steel
Test Room
Condenser room : 6,000(W) ⅹ 4.500(L) ⅹ 3.500(H)
Evaperator room : 4.500(W) ⅹ 4.500(L) ⅹ 2.800(H)
Wind Chamber Condenser room : 1,500(W) x 2,200(D) x 1,500(H)
Evaperator room : 400(W) x 300(D) x 500(H)