- Specifications - |
| |
|
|
SEOUL-NVH-100Series
|
|
System |
Air compressor, Heat exchanger, Pipe line system |
Compressed Air |
6kgf/cm2 |
Safety Device |
Heater E.O.C.R, SCR over current, Pressure H.P S/W
High temperature : High Limit cut off |
| Inlet Pressure |
0.5 ~ 1.5 kg/cm2
|
| Temperature |
Hot temperature 80 ~ 100 (¡¾3) degree
Cold temperature -10 ~ 0 (¡¾3) degree |
Coolant
Flow Rate |
20~ 100LPM |
Ambient Temperature |
25 (¡¾ 5) degree |
Test Cycle |
1Cycle/Minutes 20SEC. Dewell@ Hot & Cold Temp. |
Refrigerator |
Comp.30HP * 2EA (GAS R-22) / Water cold condending system |
| Test Cell |
1400(W) * 8000(H) * 1000(D) |
Water proofing |
Pressure Transducer |
0 ~ 5 kg/cm2 (¡¾)0.75% FS |
| Temperature Sensor |
-50 ~ 150 degree, TC T-type, Diameter:1/8" STS sheath |
|
|
Construction
|
| Material |
Rolled Acrylic & Stainless & Aluminum |
|
|
|
| |
Control |
| Control |
Manual / Full Automatic |
|
LabVIEW SoftWare With PC Interface |
|
|