Home
English
Japanese
 
 
 
¡Ü Experiments inter cooler(Thermal Cycle) of the wide selection
¡Ü The various safety device is embodied
¡Ü Controls all functions from software
¡Ü Guarantees the test which is stabilized
¡Ü Supports a calibration mode (S/W)
¡Ü Also the order production for the customer is possible
 
- Feature -
 
Test room - Chamber
Charged air pressurized
system - Air compressor &
Pipe line
Charged air temperature
control system - Heater &
Cooler
Instrumentation - Sensor &
Converter
Indicator - Controller,
Counter, Timer & Indicator
DAS - Field Point & Labview
S/W
- Specifications -
 
MODEL
SEOUL-RHP-1000Series
System
Air compressor, Heat exchanger, Pipe line system
Compressed Air
5kgf/cm2
Safety device
Heater E.O.C.R, SCR Over Current, Pressure H.P S/W
High temperature : High limit cut off
Pressure Range
0 ~ 206 kPa(0 ~2.1kg/cm2)
Air Temperature
160 (¡¾ 5) degree
Pressure Frequency
90 Cycle/min, Sinusoidal wave
Ambient Temperature
25 (¡¾ 5) degree
Total Test
Cycle
1,000,000 Cycles
Refrigerator
Capacity : 10HP, Type: Hermetic Refrigerant: R22
Test Room
2.6m(W) * 1.7m(H) * 1.0m(L)
Insulation : Poly urethane 100t
Gas Mass
Flow Meter
Flow Rate : 1088kg/hr(high), 81.6kg/hr(Low) Max: 41.3bar
Coolant Mass
Flow meter
Flow Rate : 0 ~250L/min Max: 42.3bar
Construction
Material
Rolled Acrylic & Stainless & Aluminum
Sizing
 
Control
Control
Manual / Full Automatic
Control Interface
LabVIEW SoftWare with PC Interface