Home
English
Japanese
 
 
 
¡Ü Examines the durability and an internal pressure of the        Eva./Cond.
¡Ü The various safety device is embodied
¡Ü Controls all functions from control Panel
¡Ü Guarantees the test which is stabilized
¡Ü Internal security camera
¡Ü Also the order production for the customer is possible
 
- Feature -
 
Test room - Chamber
Recever Tank - Safety glass
& Safe watch
Oil Loop System - Drain
valve & Return valve
Safety Device - Emergency
stop switch, Shot breaker
Control Panel - Controller
, Counter, Timer & Indicator
Instrumentation - Sensor &
Converter
Control switch & Alarm
detection - PLC Control
- Specifications -
 
MODEL
SEOUL-RHP-1000Series
Interior Chamber
SUS 304 Polished Steel(1T)
Exterior Chamber
SS41C
Safety Device
Heater E.O.C.R, SCR Over Current, Pressure H.P S/W
High temperature : High limit cut off
Pressure Range
0 ~ 350kg/cm2
Oil Tank
Size
1000(W) * 700(D) *350(H)
Pressure Rising Time
350kg/cm2 within 2sec, 0 ~ 200kg/cm2 within 10sec
( No Load ) , 200 ~ 350kg/cm2 within 15sec( No Load)
Pressure Falling Time
350kg/cm2 ~ 0kg/cm2 within 10sec
Pressure Control
Manual & Auto feedback PID
Oil Pump
Hydraulic System(Bosch)
Test Room
2200(W) * 1200(H) * 1500(D)
Leakage sensor, Exhaust fan, Video camera
Door Type
2100(W) * 70(D) * 1400(H) Manual lock Ttype
ReceIver Tank
Order
Construction
Material
Rolled Acrylic & Stainless & Aluminum
Sizing
 
Control
Control
Manual / Full Automatic
Control Interface
LabVIEW SoftWare With PC Interface